By: Ulf Wolf Water, in large quantities, can be overwhelming. From Noah’s Ark in biblical times, to the Johnstown (Pa.) Flood in 1889, to the 2004 tsunami in the Indian Ocean, water can be as much of a troublesome part as fire. But in smaller quantities, water can be good. You glug down a couple of glasses of it every day to stay healthy. You wash your car with a bucket full of it, or a load of clothes with a bit more. In even smaller quantities—when it is condensed and diffused, and normally called moisture, it can trigger as much heartache as a flood or other act of nature, particularly in the construction industry. Wetness can be a villain that everyone faces at some point or other. In a nation such as the United States, with many different climates and weather-zones, fighting moisture intrusion and subsequent damage calls for uncommon products and tactics depending on where in the country the war is being waged. Part of this article surveys many of AWCI’s contractors to establish widespread use of tactics and products in an assortment of areas, but first, let’s review some basics. Three Water Flavors Moisture, which is to say water, comes in three different flavors: solid (ice), liquid (water) and gas (vapor). Most builders have a respectable handle on the solid variety, and—especially in the South—have little or no trouble keeping it out of buildings. Many also have a fairly good handle on the liquid form. If anything is causing headaches nowadays, it is vapor. Maria Spinu, Ph.D., of DuPont Building Innovation, has made a brilliant occupation of studying and combating vapors especially, and has this to share about it—and the dew point temperature—in an announcement for one of her 2005 lectures: "Water exists on earth in three physical states that can undergo reversible phase transformations. Dew point temperature is the onset of the vapor-to-liquid alteration known as condensation. "Moisture problems in structures are the result of liquid water accumulation within the building enclosure. The sources of liquid water within a building enclosure include liquid water intrusion or condensation of excess water vapor transported by air currents or through diffusion. "Dew point temperature is the temperature at which the concentration of water vapor reaches its saturation and will condense on cold surfaces to mold droplets of water. We often see condensation on windows or further cool building surfaces. This so-called surface condensation is not much of a problem. However, when condensation occurs within a building assembly (interstitial condensation) it can lead to moisture problems, which range from building durability and performance, to indoor environmental quality (IEQ).” Envelope Penetration The purpose of a building’s envelope is to hold the internal environment separate—and protected—from external conditions. This includes keeping the cold (or the heat) out and the heat (or the cold) in. Another purpose of the envelope is to keep moisture out. According to the McGraw-Hill Construction’s Continuing Education Center’s course on air barriers (January 2006), "Moisture, when it does enter the building, moves through the envelope as liquid water or as water vapors. The difference between the two physical states of water is the size of the molecular aggregates: fluid water exists as significant molecular aggregates (up to 100 molecules at room temperature), while water vapors exist as free molecules. As a result, the transport mechanisms are different for liquid water and water vapors.” Liquid Water. The main source of liquid water for above-grade walls is rainwater, which can find its way behind the exterior cladding and so be driven into the building enclosed space by four main forces: • Gravity, which can draw water through openings and cracks, and into the construction assembly. • Capillary forces, that will act like a sponge sucking water through small cracks and pores. Smaller cracks result in greater capillary forces. • Rain droplets can pass through openings in the exterior cladding, driven by the drive of the falling rain. • The pressure differential can push or suck water through openings and cracks, into the construction assembly. Water Vapor. When moisture enters the building as water vapor, it enters the envelope either by air currents or by vapor dissemination. For vapor diffusion to occur there has to be both a driving force and a conduit. In this case, the driving force is the difference in water vapor concentration (or difference in vapor pressure) across an assembly: Water vapors flow from an area of higher concentration (higher vapor pressure) to an area of lower concentration (decrease vapor pressure). However, looking at the practical side of things, experts approximation that the amount of moisture vapor shifted by air currents can be 100 to 200 times higher than the amount shifted by diffusion, and can account for more than 98 percent of all water vapor advance through the building envelope. The air current rule of thumb: Vapor flows from warm (high pressure) to cold (low pressure). The Vapor Barrier Keeping the moisture out (and away from insulation, where it can do major damage) is the principle of the vapor barrier. The main design decision is where, exactly, to place it, especially because vapor, reaching a vapor barrier and with nowhere else to go, will eventually accumulate, reach a dew point and turn into liquid water. Heating or Cooling Climate. In a heating average temperature—where a building is heated more days of the year than cooled—the vapor (by the warm-to-cold principle) will prevalently travel toward the exterior. In the cooling climate the opposed it true: Vapor will predominantly travel from outside the envelope toward the inside of the building. Since barrier membranes are more often than not placed adjacent to wall insulation, the issue of where, precisely, you place it is determined by the prevalent vapor direction. If you happen to put it incorrectly—i.e., at the far side of insulation—as the vapor travels, condensation is likely to occur inside the insulation and degrade it considerably over time. Fiberglass can lose as much as 70 percent of its insulating properties when wet. It is therefore crucial to place the barrier at the near side of insulation—as the vapor travels—so that steam hits the barrier ahead of entering insulation. In a heating climate, that means placing the barrier in between the inside of the building and the insulation; in a cooling climate, between the outside of the building and the insulation. Who Determines Placement? When it comes to determining not only the risk for moisture intrusion, but the products—and their precise placement—to guard against it, the architect calls the shots. As Bill McPherson of Central Ceilings in Massachusetts succinctly put it: "We do not devise, or propose, solutions. We implement them.” This sentiment is echoed throughout the country, where it is always up to the designer or the architect to detect and solve potential wetness issues. But there is one interesting forewarning: According to Pat Arrington of Commercial Enterprises in New Mexico, the builder license in his state lays the ultimate responsibility for any building problems at the contractor’s feet, whether he followed incorrect design information or not. So, New Mexico contractors, watch out. Gregg Conrad, president of CSW, Inc. in North Carolina, adds to that that if he notices something wrong as far as fighting moisture goes, he would "raise a flag. Even though the engineer specifies the system, and we’re only responsible for applying it appropriately, if there’s an inconsistency in the design we have to make them conscious of it.” An Engineering View Jim Stump is a Portland, Maine–based engineer with Criterium Engineers, a company of consulting engineers with more than 70 offices in North America. His view on moisture problems/solutions is well worth sharing: "Of course, moisture intrusion is always through the building envelope. How that occurs here in Portland, Maine, however, is different from how it occurs in North Carolina, and certainly unlike from, say, Phoenix, Ariz. "The vapor barrier needs to be on the warm side of the insulation. That is the basic criteria. So, in the South, where the warm side of the insulation is more often than not the outside, and you are attempting to cool the inside, the vapor barrier would be in the direction of the outside of the building. "In northern climates like here, it’s the contradictory. The warm side of the building in the wintertime is the inside; the cool side is on the outside, so the vapor barrier should be toward the in the interior. "The difficulty with design comes in climates that are in-between, states like New Mexico or the mid-Atlantic states like Virginia or North Carolina, which you get both. "The vapor moves from hot to cold, and when it reaches the dew point it will condense, and if that happens to be in the insulation, subsequently you have a problem. "A critical issue when evaluating a construction for moisture solutions is to view the building as an organic whole, and take all aspects into consideration. "The climate is just one factor. You also have to evaluate airflow, design, specific location—a building on top of a hill will behave quite differently from one down in a valley—the type of heating deployed, the type of cooling used. How much sun does it get? Is it a solar building? All of these things relate to the organic sum total that you should to consider.” Fiberglass Insulation. As mentioned earlier, fiberglass degrades greatly whilst wet. Why precisely is that? "Fiberglass insulation,” explains Stump, "relies on air pockets, and as soon as it gets wet it loses those air pockets and, therefore, loses its insulation value.” As much as 70 or 80 percent? "It’s certainly possible. And I, unfortunately, see that phenomenon quite often.” Wood Framing. Stump has this to offer: "Some designers advise that when it comes to wood-framed walls, you should put a vapor barrier on both the inside and the outside to try to seal the wall. "My experience is that, although this may look good on paper, in practice—because no barrier is ever 100 percent effective—you’re going to wind up trapping moisture inside that wall. "You have to consider that the wood frame has quite a bit of moisture in it already, even if it is a kiln-dried piece of lumber. Over time, it will lose some of that moisture, and this has to go somewhere. If sealed in, it will in the end reach dew point and condense inside the wall.” Taking the Country’s Moisture Fighting Pulse What products are used where? Keeping in mind that the contractor as a rule does not choose, nor recommend, the moisture fighting weapons he deploys, the question becomes as a substitute: Which products does he normally install (as specified by the architect)? The brand names you would expect to hear are the names that popped out of the mouths of contractors from all over the country; it is their preferences in item for consumption type that vary. Gabriel Castillo of Pillar Construction in Virginia likes liquid-rolled on membranes, which become part of the substrate. "When the liquid applied membrane dries, it hardens to a rubber-like, waterproof membrane, so you know that it will envelop and seal well. There are no pores, no holes, no way for moisture to penetrate. … You just roll it on. It’s as if you were to apply a very thick paint.” Stephen Angell, president of Cape Cod Plastering in Rhode Island, uses "a self-healing, peel-and-stick creation, for external cladding.” Robert Aird of Robert A. Aird, Inc. in Maryland does of lot of exterior insulation and finish systems and sees the gamut when it comes to product names, but he cautions about maintaining the integrity of the entire system: "Some [barriers] can be used with other products, but as a rule they are only tested and approved to work with their own EIF system. He goes on to say, "In the last 10 years or so, though most actively over the last three or 4 years, we tape all sheeting joints, we spot the screw heads, we seal all penetrations and connections to other materials, and then put on a liquid-applied barrier over the complete face of the building to create an air- and water-barrier—or a WRB, a weather resistant barrier.” But in Florida, Eric Boulanger of Boulanger Drywall Corporation does not frequently see liquid applied membranes being applied. Gerald Roach of Forks Lath & Plaster in North Dakota mostly sees the big brand names, but adds that "it’s also getting more common to do a sprayed-on or trowelled-on moisture barrier over the sheeting, in particular on bigger jobs like the Wal-Marts and motels.” Glenn Sieber of Easley & Rivers, Inc. in Pennsylvania says, "What we now see more and more of is studs, sheeting, then a spray-on or a trowel-on or a place-and-press membrane for waterproofing—then a rigid insulation.” Richard Riley of Simpson Commercial Contracting, Inc. in Alabama: "On the exterior perimeter substrate we like to use a roller applied barrier, because they’re seamless. On the exterior wall—if we’re worried about dampness—we normally use an elastomeric finish.” Riley adds that all the major brands work. The moral of this story is that if you can smell it, you missed a turn way earlier there, and you’re now facing damage control, literally … which usually means more than a few pounds of cure. The ounce of prevention is to understand how moisture travels, and how to channel its movement. Coeur d’Alene, Idaho–based Ulf Wolf writes for the construction business as Words & Images.
Article Source: http://www.articlecontentprovider.com/articlesubmit
Water, in large quantities, can be overwhelming. From Noah’s Ark in biblical times, to the Johnstown (Pa.) Flood in 1889, to the 2004 tsunami in the Indian Ocean, water can be as much of a troublesome part as fire.
Bob has the following blogs, basement waterproofing and crawl space moisture and basement waterproofing michigan and basement waterproofing michigan.
Please Rate this Article
5 out of 5 4 out of 5 3 out of 5 2 out of 5 1 out of 5